Printronix L1524 Manuel d'utilisateur Page 77

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 148
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 76
3–37Configuring the Printer
Host Interface: IEEE 1284 Parallel Parameters
Host
Interface
TOF
Action
Buf
fer Size
In K
Disable*
Enable
Reset*
Do Nothing
1
2
4
6
8
16
32
64*
128
* = Factory Default
1
= If Installed
IEEE 1284
Centronics
Dataproducts SerialAutoswitchingCoax Twinax
Ethernet
1
Prime Signal
A
vailable only
in CT option
A
vailable only
in CT option
Figure 3–10. IEEE 1284 Menu
The IEEE 1284 interface is faster and more versatile than that of the Centronics
interface and supports bidirectional communication. The configuration of this
interface is controlled from the host.
Prime Signal
Enable. This parallel port will perform a warm start (reboot) when the
host asserts the Prime Signal.
Disable. This parallel port will not perform a warm start (reboot) when
the host asserts the Prime Signal.
TOF Action
Reset. A form feed is done before a warm start when the Prime Signal is
asserted from the host. This setting is used only if the Prime Signal
parameter is asserted.
Do Nothing. Nothing occurs before a warm start when the Prime Signal
is asserted from the host.